Orientation-independent liquid extraction from non-collapsible recipient

Home Orientation-independent liquid extraction from non-collapsible recipient

Orientation-independent liquid extraction from non-collapsible recipient

Back to technology needs

Technology need

Orientation-independent liquid extraction from non-collapsible recipient

Summary of the technological need

A technology to extract a liquid from a medical vial in every orientation, without introducing bubbles.

Background

For a medical application, there is a need to be able to extract liquid (medication or other) from a vial (non-collapsible glass recipient with rubber septum) in a broad range of orientations, preferably all orientations. As liquid is removed from a vial, air replaced the extracted volume. As gravity pulls the liquid downwards, this might result in the extraction of air, which is not desirable.

We are looking for technologies which are able to extract liquid from a non-collapsible recipient, which are not affected by the orientation of the recipient. This can be either 1. guaranteeing that liquid (no air) is always extracted 2. separating air from the liquid, in case air would be extracted 3. detecting that air has been extracted, in case air would be extracted The first solution is the preferred route.
Background and Description Provide the

Application domains

pharma

Specifications

This is a medical drug delivery application in which glass vials have a volume of 2-10ml and have standard dimensions as currently used on the market. The liquids have a water to light oil-like viscosity.

Further info regarding technical performance

    Vials of 2-10ml
    Extraction flow rate of approx. 0.1 to 10ml/min
  • Glass vials (non-collapsible, no stopper) with standard cap & septum
  • Water to oil-like viscosity
  • Dimensions/volume of final technology should be limited (portable device) to handheld shape/volume
  • Preferably mechanical design (no need of electric power)